background image

PLUG

FUEL

LINES

U-BOLTS (2)

LEADS #229

AND #242D

{

FIGURE F.20 – FUEL TANK REMOVAL DETAILS

STATOR/ROTOR REMOVAL AND REPLACEMENT (CONTINUED)

PROCEDURE

Refer to Figure F.20.

1. Turn the engine off and disconnect battery leads

and drain fuel.

2. Perform the Case Cover Removal procedure,

including removing the output panel.

3. Perform the Chopper Module / Output Rectifier

Bridge Assembly Removal Procedure.

4. Perform the Chopper Module Capacitor

Discharge Procedure.

5. Disconnect Battery.

6. Using the 3/8" wrench, remove leads #229 (white)

and #242D from the fuel level sensor. Label the
leads for reassembly.

7. Turn the fuel off at the shutoff valve. Remove and

plug the fuel return line.

8. Remove and plug the lower fuel line. Pull it

through the firewall.

9. Using the 9/16" deep socket wrench, remove the

four lock nuts, washers, and rubber washers from
the fuel tank mounting U-bolts.

10. Carefully remove the U-bolts and lift the fuel tank

from the machine.