Troubleshooting and repair, 0 volts 50v 5ms, Normal open circuit voltage waveform (stick) – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation

Page 236

Advertising
background image

0 volts

50V

5ms

This is the typical DC open circuit out-
put voltage generated from a properly
operating machine in the Constant
Current (CC)mode.

Note that each vertical division repre-
sents 50 volts and that each horizon-
tal division represents 5 milliseconds
in time.

SCOPE SETTINGS

Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (STICK)