MAINTENANCE

D4.7

D4.7

VANTAGE® 500

WELDER/GENERATOR
MAINTENANCE

STORAGE: Store the Vantage 500 in clean, dry, pro-
tected areas.

CLEANING: Blow out the generator and controls peri-
odically with low pressure air. Do this at least once a
week in particularly dirty areas.

NAMEPLATES: Whenever routine maintenance is per-
formed on this machine - or at least yearly - inspect all
nameplates and labels for legibility. Replace those
which are no longer clear. Refer to the parts list for the
replacement item number.

BRUSH REMOVAL AND REPLACEMENT: It is normal
for the brushes and slip rings to wear and darken slight-
ly. Inspect the brushes when a generator overhaul is
necessary.

Do not attempt to polish slip rings while the engine is
running.

BEARINGS: The Vantage 500 is equipped with double-
shielded ball bearings having sufficient grease to last
indefinitely under normal service. Where the welder is
used constantly or in excessively dirty locations, it may
be necessary to add one half ounce of grease per year.
A pad of grease one inch wide, one inch long, and one
inch high weighs approximately one half ounce. Over-
greasing is far worse than insufficient greasing.

When greasing the bearings, keep all dirt out of the
area. Wipe the fittings completely clean and use clean
equipment. More bearing failures are caused by dirt
introduced during greasing than from insufficient
grease.

RECEPTACLES:

Keep the electrical receptacles in

good condition. Remove any dirt, oil, or other debris
from their surfaces and holes.

CABLE CONNECTIONS:

Check the welding cable

connections at the weld output terminals often. Be sure
that the connections are always tight.

WARNING

TABLE D4.1

Cummins B3.3 Engine Maintenance Components

ITEM

MAKE

PART NUMBER

SERVICE INTERVAL

Air Cleaner Element

Donaldson

P181052

Replace every 200 hours. (Replace more

AC

A302C

often when used in dusty and / or

Fleetguard

AF437K

high ambient temperature conditions)

Oil Filer

Cummins

C6002112110

Replace every 750 hours or 12 months,

Fleetguard

LF3855

whichever is less.

Fan Belt

Cummins

C0412021748

Inspect every 1000 hours or 12 months,

whichever is less.

Fuel Strainer

Cummins

3826094

Inspect and replace monthly, as

Fleetguard

FF5079

required. Replace annually.

Fuel Filter /

Cummins

C6003112130

Replace every 500 hours or 6 months,

Water Separator

Fleetguard

FS19594

whichever is less.

.

Battery

-----

BCI GROUP 34

Inspect every 500 hours

Engine Oil Change

See Manual

-----

Change every 750 hours or 3 months,

whichever is less. Check daily.