Troubleshooting and repair, Caution – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation

Page 195

Advertising
background image

FUNCTION PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

CAUTION

The machine control is still active
when the remote control unit is
attached.

1. This is normal in TIG mode.

2. The remote control unit may be

defective.

3. Check the Amphenol connec-

tions and associated wiring.

1. Check Plug J11 on the Weld

Control PC board for loose or
faulty connections.

2. The Weld Control PC board

may be faulty.

The machine seems locked into the
CC mode of operation (Stick mode).

1. Check the position of the MODE

SELECTOR switch. It must be
in the correct position for the
process being used.

1. Check the MODE SELECTOR

switch and associated leads.
See the Wiring Diagram.

2. The Weld Control PC board

may be faulty.

TROUBLESHOOTING AND REPAIR