Installation – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation

Page 148

Advertising
background image

INSTALLATION

A5.2

A5.2

VANTAGE® 500

TECHNICAL SPECIFICATIONS - VANTAGE 500 CUMMINS (K2406-1)

INPUT - DIESEL ENGINE

Make /Model

Description

Speed (RPM)

Displacement

Starting

Capacities

System

CUMMINS

4 cylinder

High Idle 1890

199 cu. in

12VDC battery

Fuel

B3.3

53HP (40 kw)

Low Idle 1400 (3.3L)

& Starter

25 US gal.

Diesel Engine

@ 1800 RPM

Full Load 1890

(94.6L)

Bore x Stroke

Oil:
2 US gal.

3.74” x 4.53”

(7.6L)

(95mm x 115mm)

Coolant

2 US gal. (7.6L)

RATED OUTPUT @ 104°F(40°C) - WELDER

Duty Cycle

Welding Output

Volts at Rated Amps

100%

500 Amps (DC multi-purpose)

40 Volts

60%

550 Amps (DC multi-purpose)

36 volts

50%

575 Amps (DC multi-purpose)

35 volts

PHYSICAL DIMENSIONS

Height

(2)

Width

Depth

Weight

42.0 in

31.5 in.

63.1 in.

1443lbs.

(1066.8 mm)

(800.1mm)

(1603mm)

(655kg)

(Approx)

1.

Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2.

Top of Enclosure. Add 7.0” (177.8mm) for exhaust.

OUTPUT @ 104°F(40°C) - WELDER AND GENERATOR

Welding Range

30 - 575 Amps CC/CV

20 - 250 Amps TIG

Open Circuit Voltage

60 Max OCV @ 1900 RPM

Auxiliary Power

(1)

120/240 VAC

12,000 WATTS, 60 Hz., Single Phase

20,000 WATTS, 60 Hz., Three Phase

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising