Nstallation – Southbend TVGS-32SC Manuel d'utilisation

Page 18

Advertising
background image

I

NSTALLATION

T

RU

V

ECTION

G

AS

C

ONVECTION

O

VENS

P

AGE

18

O

WNER

S

M

ANUAL

1194658

IN

S

TA

LL

A

TI

O

N

Step 6: Connect Electricity

!

WARNING

ELECTRIC GROUNDING INSTRUCTIONS

This appliance (120V ovens only) is equipped with a three-prong (grounding) plug for your protection

against shock hazard and should be plugged directly into a properly grounded three-prong

receptacle. Do not cut or remove the grounding prong from this plug.

NOTICE

This appliance, when installed, must be electrically grounded in accordance with local codes, or in the

absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical
Code, CSA C22.2
, as applicable.

Wiring diagrams are located on the side of the control panel assembly, as well as in this manual (beginning

on page 34). Be sure that the input voltage and phase match the requirements shown on the serial plate,

which is located inside the lower front panel.

Ovens ordered to operate on 120V power have a three-wire cord. (Double-deck ovens have two power
cords, and triple-deck ovens have three cords; one for each oven.) Each cord has a three-prong plug that

fits any standard three-prong grounded receptacle. Single-deck units require a 15 ampere supply, while

double-deck units require a 20 ampere supply, and triple-deck ovens require a 30 ampere supply. (120V

ovens shipped to Canada do NOT have factory installed power cords, and must be wired as described

below.)

Ovens without a power cord have a terminal block. The electric supply must be brought through the service

panel in the rear of the oven and connected to the terminal block. See the wiring diagrams in this manual

(beginning on page 34). The unit must be adequately grounded. Use 167°F (75°C) or better wire for all

supply lines.

Ovens are factory-equipped with a two-pole terminal block, located behind a cover plate located on the rear

of the oven. To connect the supply wires, remove the cover plate, then route the supply wires and the

grounding wire through the strain relief fitting to the terminal block. Insert the supply wires, one each, into

the two poles of the terminal block and tighten the screws. Insert the ground wire into the grounding lug and

tighten the screw. Re-attach the cover plate.