Pcb3, Control bd, Ci de commande pcb3 del de diagnostic – Hypertherm Powermax1250 Rev.4 Manuel d'utilisation

Page 84

Advertising
background image

6-5

3

U22

U23

(VISIBLE FOR 10 SEC. AFTER EVENT)

TORCH STUCK OPEN

40 POSITION RIBBON CABLE

(VISIBLE FOR 10 SEC. AFTER EVENT)

129683

WIRE GROUP

123607

123603

003206

NA

041667

POWER SWITCH (S1)

MACHINE INTERFACE CABLE

POWER BD (PCB2)

FILTER (PCB1)

CONTROL BD (PCB3)

123603

041660

003206

041667

041663

041707

80 AMP UNIT

1.41 X Vac

129652

200-600vac

750

INPUT VOLTAGE

Vbus (Vac>541vac)

CORD

Vbus (Vac<540vac)

750

NA

129653

70

50

STATUS

GAS

45

60

55

65

75

80

85

TSO

SP

SPARE

0.10uF

009994

33

J4

108171

39

40

37

38

35

36

34

008924

0.01uF

100VDC

009990

TP1

IFB

ITF

VACR

C41

50V

R50

100

009073

C52

32

30

31

28

29

26

27

22

25

24

23

21

19

20

009994

VBUS

+5

C1

0.10uF

50V

+5

/IOC

009115

10

R4

R3

10

009115

TEMP

PCB4

SENSOR BD

HEATSINK

SENSOR

SA

PRESSURE

1

3 2

B

Y

J5

R

TEMP

SENSOR IN

XFMR

T2

J21

2

B

R

1

3

B

2

X

SA

FAN

Y

1

J2

1

R

2

B

J1

GAS SOLENOID

SA

B

3

2

R

1

J20

X

+24

10

R117

10

009115

009115

R116

+5

+5

DIAGNOSTIC LED'S

START SIGNAL VALID

INVERTER INTERLOCK

(BLINKING @ 1 SEC. RATE)

SELF DIAGNOSTICS FAILURE

INSTALL JUMPER 108056 CE UNITS ONLY

PCB3

CPA

NORMAL

GOUGE

CURRENT

DOWN

MID

UP

CONTROL BD

P1

XFR

SDF

IF

TRANSFER

START

(PE)

BRN

GRN/YEL

BLK

BLU

CE UNIT

CORD

S1

J1

AUX

FILTER

PCB1

J2

(PE)

RED

GRN

AUX

DOMESTIC UNIT

BLK

WHT

S1

CORD

3

10

7

11

18

17

15

16

13

14

12

10

8

9

6

7

4

5

D8

C18

50V

0.10uF

009994

5.1V

1N5231B

109109

OUTB

R22

R8

009883

1/2W

2.21K

009414

499

009036

OUTA

8

+V

7B

-V

7C

9

R7

2.0K

3

1

109223

55V

IRLZ44N

0.022ohm

C13

0.10uF

50V

009994

2

/MM

+24

Q1

2

3

1

J3

B

Y

1

+24

PE

2

MTG-4

1

3

2

4
5
6

3B 3C
4B 4C

6B 6C

5C

5B

13
12
11

1C

1B
2B 2C

16

14

15

042188

ULN2003A

U1

/PREFLOW

/SSR

/PA

t

60V 0.20A

RT7

109024

BRIDGE

~

-

~

~

D24

INPUT

+

GND

CONTROL

-6

COMT

18REG

18T

COMINV

18INV

FLYBACK

SUPPLY

POWER

SYSTEM

T1

18PA
COMPA

+5

+10

+24

PE

CKT

PFC

CONTROL

POWER BD PCB2

SOFT START

K1

VacR

I

Vbus

1

3

2

J8

PFC

IGBT

Q7

C94

+

2

1

J6

3

2

Vbus

OR J10

J9

PFC CHOKE

C98

+

J7

1

POWER

TRANSFORMER

20 OHM

YEL

J13

YEL

P2

50W

BRN

BRN

INVERTER

IGBT

Q6

T2

ITF

SENSOR

J19

/MM

+24

4

3

COMT

18T

2

1

12

10

11

INTERFACE

GND

CHASSIS

BLK

GRN/YEL

YEL

12

13

14

MACHINE

START

WHT

RED

3

4

CAP

1

COMT

8

9

6

7

4

5

2

3

J18

J17

CKT

J14

WHT

RED

NOZZLE

ELECTRODE

WORK LEAD

TRANSFER

IFB

CURRENT

SENSOR

FEEDBACK

J12

IGBT

PILOT ARC

NC

INDUCTOR

OUTPUT

B

R

OUTPUT

DIODES

J11

7.5 ohm

100W

NA

1.41 X Vac

750

750

NA

60 AMP UNIT

087000(DOMESTIC)

087007(CE)

083169(DOMESTIC)

083170(CE)

1/3PH

230-400vac

3PH

200-600vac

1/3 PH

230-400vac

3PH

TEMP SENSOR BD (PCB4)

041723

041723

TIMING DIAGRAM

013341

013341

129652

129726

129732

123603

123603

005257

005257

041746

041746

041709

041710

041713

041713

013341

013341

041773

LOCKOUT

VIO

ORG

BLUE

129739

NOTES:
1. PIN 6 IS KEYING FEATURE ON 60A
2. PIN 9 IS LOCKOUT FEATURE

6

5

+

-

+24

24VDC @100MA MAX

TOLERANCES ARE:

UNLESS OTHERWISE SPECIFIED:

2 PL DECIMAL ±.01

FRACTIONS ±1/64
ANGULAR ±.5∞

DIMENSIONS ARE IN INCHES.

3 PL DECIMAL ±.005

PART MUST BE FREE OF BURRS AND SHARP
EDGES. BREAK SHARP EDGES IF NECESSARY
WITH CHAMFER OR RADIUS .015 MAX.

PURPOSES WITHOUT PERMISSION

FOR MANUFACTURING OR FABRICATION

FROM HYPERTHERM, INC.

THIS DRAWING AND ALL INFORMATION

PROPRIETARY AND MAY NOT BE USED

CONTAINED THEREON IS CONSIDERED

MATERIAL

1=1

1 OF 1

SCALE

Box-5010 Hanover, NH 03755-5010 603/643-3441

SHEET

8

7

6

3

5

4

2

1

A

B

C

D

8

7

6

3

5

4

2

1

A

B

C

D

C

CI DE COMMANDE

PCB3

DEL DE DIAGNOSTIC

SIGNAL D’AMORÇAGE VALIDE

TRANSFERT

DÉFAILLANCE DE L’AUTODIAGNOSTIC
(CLIGNOTEMENT TOUTES LES SECONDES)

TORCHE BLOQUÉE EN POSITION OUVERTE
(VISIBLE PENDANT LES 15 SECONDES QUI SUIVENT

L’ÉVÉNEMENT)

RECHANGE

CÂBLE RUBAN 40 POSITIONS

MONTER LE CAVALIER DE L’APPAREIL 108056 CE UNIQUEMENT

INTERVERROUILLAGE DE SÛRETÉ DE L’ONDULEUR
(VISIBLE PENDANT LES 15 SECONDES QUI SUIVENT

L’ÉVÉNEMENT)

APPAREIL 80 A

APPAREIL 60 A

087000(Domestique)

087007(CE)

083169(Domestique)

083170(CE)

TENSION D’ENTRÉE

200–600V c.a.

230–400V c.a. 200–600V c.a.

230–400V c.a.

mono-/triphasé

triphasé

mono-/triphasé

triphasé

Vbus (V c.a. < 540 V c.a.)

750

750

750

750

Vbus (V c.a. < 541V c.a.)

1.41 X V c.a.

1.41 X V c.a.

CORDON

129652

129653

129652

129726

GROUPE DE FILS

123607

129683

129732

129739

CÂBLE D’INTERFACE MACHINE

123603

123603

123603

123603

INTERRUPTEUR D’ALIMENTATION (S1)

003206

003206

005257

005257

FILTRE (PCB1)

041660

041773

CI D’ALIMENTATION (PCB2)

041667

041667

041746

041746

CI DE COMMANDE (PCB3)

041663

041707

041709

041710

CAPTEUR DE TEMPÉRATURE (PCB4)

041723

041723

041713

041713

SCHÉMAS DE CORRESPONDANCE

013341

013341

013341

013341