After Use:

Cleaning
1 . Clean with mild soap and water; do not submerse the simulator or parts in

cleaning fluids or water .

2 . Use only on clean surface . Avoid felt tipped markers, ink pens, acetone, iodine

or other staining products and avoid placing the simulator on newsprint or
inked lines of any kind .

3 . To ensure longevity, each simulator should be cleaned after each training

session and a general inspection should be conducted regularly .

4 . Modules and all other parts should be drained and air-dried thoroughly

before storage and disinfected when needed . After use of injection pads
(use water only), accumulated water should be squeezed out .

NOTE: Do

not store wet foam pads in the skin . To prevent mildew or mold, pads can
be soaked in a mild solution of disinfectant and water or bleach and water .
Squeeze excess solution from pads, allow them to dry, then store or reinsert
in simulator .

5 . Articulating parts will benefit from a light application of talcum powder prior

to training sessions .

Extend Cleanliness

To extend the cleanliness of your simulator:
1 . Use a small towel and lightly dust the simulator head and chest with a small

amount of powder (provided) . Wipe away any excess .

2 . Use gloves when handling the simulator .

Laerdal Recommends

Use only on clean surface . Avoid felt tipped markers, ink pens, acetone,

iodine or other staining products and avoid placing the simulator on

newsprint or inked lines of any kind . These will stain the simulator .

Technical Data

General
Operating Temperature:
0°C – 40°C at 90% relative humidity, non-condensing
Storage Temperature:
-15°C – 50°C at 90% relative humidity, non-condensing

ALS Simulator
Defibrillation: Average of 720 J /minute max

Emergency Cardiac Capabilities
• Synchronized variable heart rate, rhythm, abnormalities and duration
• Defibrillation (25 -360 J)

IV Arm

Accessible veins include median, basilic and cephalic

Standards/Approvals

The product is in compliance with the essential

requirements of Council Directive 2004/108/EC on

electromagnetic compatibility (EMC) .
The product is in compliance with Council Directive

2011/65/EU on restriction of the use of certain

hazardous substances (RoHS) .

Minimum Computer Requirements
• Intel i-core generation 3 or newer
• Score over 3000 PassMark - CPU Mark
• 4 GB RAM
• 120GB hard disk space
• 1366x768 or better
• Headset w/microphone
• USB ports – 2

Minimum Software Requirements
• Windows 7 or Windows 8
• 100% DPI

Replacement Parts:

For latest version of Spare Parts and Accessories, visit www .laerdal .com

Photo 27

Table of Contents

Items Included. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Skills Taught. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Teeth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Carotid Pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Tracheostomy Plug & Care. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
NG Tube Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Intubation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Lungs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Stomach Reservoir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Belly Plates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Injection Pads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Waist, Knee and Ankle Joints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Arms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Legs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
IV Arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Replacing Skin & Vein System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Blood Pressure Arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Auscultation of Heart, Breath, Bowel Sounds and Fetal Tones . . . . . . . . . . . . . . 4
Genitalia. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Colon Reservoir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Urinary Catheterization and Enema Simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Attaching Nursing Anne Modules to Manikin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

SimPad Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Care and Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Items Included:
(1) Full-Body Female Manikin
(1) Articulating Blood Pressure Training Arm (Nursing Anne SimPad)
(1) Articulating Female Multi-Venous IV Training Arm
(1) Hospital Gown
(1) Male Genitalia
(1) Female Genitalia
(3) Urinary Valves
(3) Anal Valves
(1) Simulated Blood Concentrate
(1) 100 cc Syringe
(1) Manikin Lubricant
(1) Assembly Tool Kit

Wig pictured on front cover, not included

Optional Accessories

Nursing Anne Modules:

(1) Breast Exam Module, with interchangeable abnormalities
(1) Mastectomy Module with staples and drain
(1) Fundus Module with interchangeable uteri

Wound Care & Assessment Set:

(1) Abdominal Incision Module with Painted Sutures
(1) Abdominal Incision Module with Staples and Penrose Drain
(1) Abdominal Incision Module with Nylon Sutures

and Penrose Drain

(1) Abdominal Subcutaneous Heparin and Insulin Injection Module
(1) Abdominal Packing Module
(1) Infected Colostomy Stoma
(1) Ventro-Gluteal and Gluteal Decubitus Ulcer Modules
(1) Below Knee Amputation Stump
(1) Thigh Packing and Irrigation Module
(1) Thigh Suture Module
(1) Thigh Debridement Module
(1) Varicose Vein Leg with Stasis Ulcer
(1) Diabetic Foot Module

Skills Taught:

• Basic patient handling
• Denture care

• Oral hygiene

• Eye andear irrigation

(simulated)

• NG Tube insertion, care medication administration and removal

• Tracheostomy care and suctioning
• Blood pressure skills (When

used with

SimPad)

• IV care and management
• Subcutaneous and intramuscular injection
• Oxygen delivery procedures
• Ostomy irrigation and care
• Catheterization skills
• Enema simulation

• Colonic irrigation
• Wound assessment and care
• Bandaging and dressing
• Post-surgical mastectomy-care procedures
• Recognition of breast disorders, their sizes and relative locations
• Practice of fundus massage skills
• Auscultation and recognition of normal and abnormal heart,

breath and bowel sounds and fetal tones

(When used with SimPad)

Caution: Latex

This product contains Natural Rubber latex which may cause

allergic reactions when in contact with humans.

Please contact Laerdal Customer Service

for more information on Replacement Parts in other skin tones.

E

N

G

LI

SH

E

NGLISH

Nursing Anne

1

Laerdal

The product, when carrying the CE-mark, is in

compliance with essential CE requirements and other

relevant provisions of council directive 1999/5/EC.

• Lavage/Gavage

Oral and nasal Intubation

.

English

Advertising
Ce manuel est liée aux produits suivants: