Section 5: maintenance, 01 general maintenance checks, 02 external coolant filter cleaning procedure – Tweco 30 O2 Auto-Cut Manuel d'utilisation

Page 87: Section 5: maintenance -1

Advertising
background image

Manual No. 0-4818 Auto-Cut 300

2

5-1

MAINTENANCE

SECTION 5: MAINTENANCE

5.01 General Maintenance Checks

Perform the following checks periodically to ensure proper system performance.

Power Supply Maintenance Schedule

Daily
Check coolant level; add coolant as needed.
Check gas hose connections and pressures.

Monthly
Check cooling fan and radiator; clean as needed.
Check gas hoses for cracks, leaks, or abrasion.
Replace as needed.
Check all electrical connections
for cracks or abrasion. Replace as needed.

Six Months
Clean or replace external coolant filter.
Clean coolant tank.
Vacuum out any dust buildup inside power supply.
Check internal coolant filter

5.02 External Coolant Filter Cleaning Procedure

Periodic cleaning of the coolant filter ensures maximum coolant flow efficiency. Poor coolant flow causes ineffi-
cient torch parts cooling with consequent faster consumable wear.

Clean the coolant filter as follows:

1. Disconnect the system from main input power.

Filter Screen

Filter Holder

Art # A-04811

2. Unscrew and remove the filter bowl by hand. Be sure to keep the O-ring.

3. Remove and clean the filter. Re-install the bowl, tightening it by hand. Be sure the O-ring is in place.

4. Turn the system on and check for leaks.

Advertising