Tweco 30 O2 Auto-Cut Manuel d'utilisation

Page 82

Advertising
background image

Manual No. 0-4818 Auto-Cut 300

2

4-14

OPERATION

Status

Code

If GCM 1000: Control cable not connected or Basic ID signal open.

GCM 2010 & 2000: Dirt on fiber ends or in connectors, blow out with clean
dry air; fiber not locked into connector; sharp bends in fiber; fiber
defective; Gas Control PCB defective, replace. CCM defective, replace.

3-2

Gas Control Communication
reply fault, connection was
established but CCM did
receive a reply to a process
request.

Gas Control did not reply to signal from CCM in allowed time. Dirt on fiber
ends or in connectors, blow out with clean dry air; fiber not locked into
connector; sharp bends in fiber; fiber defective. If problem persists Gas
Control PCB likely defective, replace board.

If GCM 1000, Plasma < 15 PSI; faulty or disconnected pressure SW.
If GCM2010_AG, GCM2000_AC or later or Gas Control has been updated
with 19X2219_AG or later PCB: Plasma or Shield input out of range 105-135

3-4

Gas Control not ready

Purging; not in RUN mode; Gas Control faulty, replace PCB.

3-5

Gas Control Protocol Fault

Application error or firmware compatibility fault

3-6

Invalid Current Control level
from GCM

GCM sent output current level outside the range of the power supply,
Check firmware compatibility

3-7

Gas Control returns wrong
command sequence

Check firmware compatibility

3-8

CCM and Gas Control type
(Autocut-Ultracut) mismatch

Install correct CCM or Gas Control for system

3-9

Gas Control Communication
reply fault

Reply not compatible with request; Check firmware compatibility

3-10

Warning. -- Gas Control

System will function but control may not be optimized for best

4-1

Coolant Level low fault

Check coolant level, add as needed.

Low coolant flow after power
on purge.
Not cutting: < 0.7 gal/min for 15
sec;
Cutting: flow between 0.35 to
0.7 gal/min for 3 sec. or

4-3

Coolant overheated (>70
deg. C, 158 deg F)

Coolant fan failed; radiator fins clogged with dirt; Ambient temperature >
40 deg C.

Coolant System not ready.

If new installation recycle power to restart pump, may take a few times to
fill hoses;

During power on purge /
priming, flow did not reach 0.35
gal/min for at least 5 seconds

Damaged torch coolant tube; Suction leak introducing air into coolant,
suspect rear panel filter seal; clogged filter; defective pump.

While cutting detected low coolant level, does not stop cut.
Add coolant as required.

Suction leak introducing air into coolant, suspect rear panel filter seal;
clogged filter; defective pump.

Status Code Key (cond)

Message

Cause/Remedy

3-1

Gas Control Communication
fault, Cannot establish
Communication with gas
control.

4-4

4-5

Low Coolant Level - Warning

3-3

Gas Pressure Low

4-2