Manual No. 0-4818 Auto-Cut 300

2

3-15

INSTALLATION

3.10 Connect Fiber Optic Cable to CCM

1. Remove the strain relief securing nut from the strain relief on the fiber optic cable(s). Loosen the strain

relief dome nut from the strain relief.

2. Pass the cable connector through the appropriate opening. Slide the strain relief securing nut onto the

cable. Make a loop of the cable; carefully press the cable connector into the appropriate receptacle on the
internal control module.

3. Tighten the strain relief onto the cable(s). Do not overtighten.

To Gas Control Module

To Remote HMI
(if installed)

Profile Detail, Fiber Optic Cable Installation

Cable Receptacles

To Slave Power
Supply
(if installed)

Art # A-06793