Tweco 30 O2 Auto-Cut Manuel d'utilisation

Page 83

Advertising
background image

Manual No. 0-4818 Auto-Cut 300

2

4-15

OPERATION

Status

Code

5-1

CANBUS Failure to
Acknowledge fault.

If GCM 1000, Basic ID signal missing; Other gas controls, Fiber
disconnected or broken, Transceiver (what fiber plugs into) fault, replace
Gas control PCB or CCM

CANBUS Off due to
excessive data errors;
CANBUS data error warning.
Errors increasing, will soon
fault.

5-4

CCM Message not sent

Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not
locked into connector; sharp bends in fiber; fiber defective; CANBUS
hardware error (CCM or Gas Control PCB)

6-1

CCM Analog Voltage Error

Replace CCM

6-2

CCM ADC or DAC error

Replace CCM

Torch coolant tube broken or missing;
CCM fault, replace CCM

6-4

CCM Data Memory error

Replace CCM

Status Code Key (cond)

Message

Cause/Remedy

5-2

Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not
locked into connector; sharp bends in fiber; fiber defective;

5-3

Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not
locked into connector; sharp bends in fiber; fiber defective;

6-3

Coolant Flow too High error,
flow > 2.7 gal/min

Advertising