3.15 Connect Control, Input, and Outputs to Gas Control Module

1. Make all other connections to the rear of the Module. The connections are labeled. The Module must be

grounded; the grounding terminal is marked Use #4 AWG (European 21 mm

2

) (or thicker) wire for

grounding. Keep the ground wire as short as possible.

2. Position the Module on a flat, horizontal, mounting surface.

3. Ensure that the Flowmeters are plumb.

4. Fasten the Module to the mounting surface.

5. Connect all gas / water inputs to the rear panel of the module.

CAUTION

When cutting with O

2

(oxygen) plasma, air must be connected to the Module.