Section 3: installation, 01 installation requirements, Section 3: installation -1 – Tweco 30 O2 Auto-Cut Manuel d'utilisation

Page 25: 01 installation requirements -1

Advertising
background image

Manual No. 0-4818 Auto-Cut 300

2

3-1

INSTALLATION

SECTION 3: INSTALLATION

3.01 Installation Requirements

Electric Supply

The electrical supply network, the gas and water supply system must meet local safety standards. This
conformity shall be checked by qualified personnel.

Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

50/60

74

206

260

#3/0

230

50/60

72

181

230

#2/0

400 (Incl. CE)

50/60

75

109

135

#3

460

50/60

89

112

150

#2

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electrical Code

Auto-Cut 30O2 Power Supply Input Wiring

CAUTION

Fuse and wire sizes are for reference only. The installation must conform to national and local codes for
the type of wire being used and method of installation.

Gas Supply

The customer must supply all gases and pressure regulators. Gases must be of high quality. Pressure
regulators must be double-stage and installed as close as possible to the gas console. Contaminated gas
can cause one or more of the following problems:

Reduced cutting speed

Poor cut quality

Poor cutting precision

Reduced consumables life.

Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.

NOTE

Gas supply leads must be #8 (1/2 in. ) hose or larger

Cooling System Requirements

Coolant must be added to the system on installation. The amount required varies with torch leads length.

Thermal Dynamics recommends its coolants 7-3580 and 7-3581 (for low temperatures).

Cat. Number and Mixture

Mixture

Protects To

7-3580 'Extra-Cool

TM

'

25 / 75

10° F / -12° C

7-3581 'Ultra-Cool

TM

'

50 / 50

-27° F / -3° C

7-3582 'Extreme Cool

T M

'

Concentrate*

-65° F / -51° C

Coolant Capabilities

* For mixing with D-I Cool

TM

7-3583

Advertising