06 specifications & electrical requirements, 07 system layout – Tweco 30 O2 Auto-Cut Manuel d'utilisation

Page 18

Advertising
background image

Manual No. 0-4818 Auto-Cut 300

2

2-2

SPECIFICATIONS

2.06 Specifications & Electrical Requirements

Max OCV (U

0

)

380 vdc

Minimum Output Current

10 Amps

Max Output Current

300 Amps

Output Voltage

60 - 230 vdc

Duty Cycle Rating

100% @ 300A, 180V, (54kW),

Ambient Temperature
for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.70 @ 300 A DC Output

Cooling

Forced Air (Class F)

Auto-Cut 30O

2

Specifications & Design Features

Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

50/60

74

206

260

#3/0

230

50/60

72

181

230

#2/0

400 (Incl. CE)

50/60

75

109

135

#3

460

50/60

89

112

150

#2

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electrical Code

Auto-Cut 30O2 Power Supply

2.07 System Layout

Refer to section 3.11 for ground connections and ground cables.

Primary power

CNC

Remote

Arc

Starter

Art # A-07118_AD

Coolant Supply

Coolant Return

Control Cable

Coolant Supply
w/ Negative

Coolant Return

Control

Cable

Fiber
Optic

Cable

Control

Cable

Gas Control

Module

300-A

Power
Supply

Torch

Valve

Assembly

Shield

A

B

C

D

E

P

I

J

K

L

H

Q

R

S

Shield

Plasma Gas

Shield Gas

Plasma Gas

Shield Gas

Preflow Gas

Work

Torch

Positioning Tube

Water

Shield

G

T

Pilot Return

Pilot Return

Negative Leads (2)

Work Cables (2)

50’ / 15.2 m Maximum Length

125’ / 38.1 m Maximum Length

175’ / 53.3 m Maximum Length

Advertising