Manual No. 0-4818 Auto-Cut 300

2

4-16

OPERATION

4.07 Remote Arc Starter: Service Chart

Symptom

Cause

Check

Remedy

Coolant has become conductive Use conductivity meter

Flush system,
replace coolant.

Pilot return wire not connected

Visual inspection

Connect Wire.

Spark gap set too close

Check with feeler gauge

Set to 0.063" ±0.002"

High Frequency cap (C4)
possibly open

Use capacitance meter

Reconnect or replace.

Broken or missing ferrites

Visual inspection

Replace.

Short across in inductor (L1)

Visual inspection

Remove short;
increase coil gaps.

Spark gap bus caps
(C1, C2, C3)
broken or defective

Capacitance meter

Replace.

Negative supply not
connected correctly

Visual inspection

Reconnect.

Spark gap set too large

Check with feeler gauge

Set to 0.063" ±0.002"

Faulty transformer

Resistance measurement

Replace.

No 120V supply

Check input voltage at EMI filter

Make connections;
replace harness.

No/ loose connection
to spark gap

Visual inspection

Reconnect.

Faulty EMI filter

Voltage/ Resistor measurement Replace.

Loose fitting(s)

Visual inspection

Tighten fittings.

Failure to braze joints (L1)

Visual inspection

Replace HF Coil.

Damaged or punctured
coolant line(s).

Visual inspection

Replace coolant line(s).

Supply & return hose reversed

Visual Inspection of color-coded
connections

Match coolant connection colors
to arc starter fitting colors.

Blockage in coil or
supply/return hoses

Loosen fitting slightly and check
for coolant flow

Flush system.

Shield Drain / Torch lead inner
shield connector
missing or loose.

Visual inspection of lead
attachment to Arc Starter

Reconnect / tighten
lead connectors.

Missing or loose
ground connection

Visual inspection of ground wire
to Arc Starter

Make or tighten
connections to
good ground.

Cap C5 not connected,
open or loose

Visual inspection / capacitor
measurement

Replace PCB.

Arc Starter Service Chart

Erratic System

Behavior

(EMI Interference)

No Pilot ignition:

Spark in Arc Starter

but no ignition

No Pilot ignition:

No Spark

in Arc Starter

No cooling or

insufficient cooling:

Leaks coolant

No cooling or

insufficient cooling:

No Coolant Flow