Tweco 30 O2 Auto-Cut Manuel d'utilisation

Page 36

Advertising
background image

Manual No. 0-4818 Auto-Cut 300

2

3-12

INSTALLATION

3.07 Connect Work Cable and Pilot and Negative / Torch Leads

1. Pass the ends of the work cable and pilot and negative / torch leads upward through the leads bracket at

the bottom of the power supply rear panel, and through the openings in the connections cover support
panel.

2. Refer to the illustration. Connect the leads as shown. Tighten securely. Do not overtighten.

CAUTION

The clear connections cover must remain in place.

NOTE

Negative Lead and Torch Lead are used interchangably during this operation

PILO

T

WORK

TORCH

Connection Panel

AC INPUT

L1

L2

L3

Work Lead

Torch Lead - To Remote Arc Starter

Work

Torch

Lead Connection Detail

Connections Cover
Support Panel

Art # A-07660_AB

Connections Cover

Pilot

To Cutting Table

Leads Bracket

Pilot Lead -
To Remote Arc Starter

Advertising