Manual No. 0-4818 Auto-Cut 300

2

4-4

OPERATION

Gas Control Module: Controls & Indicators

1. MODE Selection Switch

MODE

RUN

SET PREFLOW

SET PLASMA

& SHIELD

TEST

Art # A-06890

ENABLE

STATUS

DISABLE

PLASMA
POWER
SUPPLY

SHIELD

FLOW

GAS

PRESSURE

MODE

GAS

GCM
2000

PLASMA

PREFLOW

9

9

H20

MIST

RUN

SET PREFLOW

SET PLASMA

& SHIELD

TEST

Automated

Plasma Cutting System

AMPS

Thermal Dynamics

O

2

- AIR

H35 - N

2

AIR - AIR

N

2

- H

2

O

• Normally in the RUN position during torch operation.

• In the SET PREFLOW position, Preflow or Piloting gas (Air or N

2

) flows to the torch allowing the operator to

adjust pressure. Gas automatically shuts off after 2 minutes if left in the SET PREFLOW position.

• In the SET PLASMA & SHIELD position, selected cutting gases, Plasma & Shield, flow to the torch to allow

operator to set the pressure (regulator & gauge) and flow (knob at top of flowmeter). Gases automatically shut
off after 2 minutes if left in the SET PLASMA & SHIELD position. GCM 2000 gas control revision AC or later
includes inlet pressure sensors. In SET PLASMA & SHIELD if either gas pressure is outside the range of 100-
135 PSI the Status LED will blink a code fo 3 blinks followed by a space then repeating the 3 blinks. User must
determine which gas has to be adjusted.

• TEST mode will also cause selected PLASMA & SHIELD gasses to flow to the torch.