22 ControlLogix® Controller and Memory Board

Publication

1756-IN101J-EN-P - November 2004

Connect a Battery

WARNING

When you connect or disconnect the battery an electrical
arc can occur. This could cause an explosion in
hazardous location installations. Be sure that power is
removed or the area is nonhazardous before proceeding.

For Safety information on the handling of lithium
batteries, including handling and disposal of leaking
batteries, see Guidelines for Handling Lithium Batteries,
publication AG 5-4.

ATTENTION

To prevent possible battery leakage, even if the BAT LED
is off, replace a 1756-BA1 or 1756-BA2 battery according
to the following schedule:

ATTENTION

Store batteries in a cool, dry environment. We
recommend 25

°C with 40%…60% relative humidity. You

may store batteries for up to 30 days between
-45

°…85°C, such as during transportation. To avoid

leakage or other hazards, do not store batteries above
60

°C for more than 30 days.

If the temperature 1 in.
below the chassis is:

Replace the battery within:

0

° … 35° C

No required replacement

36

° … 40° C

3 years

41

° … 45° C

2 years

46

° … 50° C

16 months

51

° … 55° C

11 months

56

° … 60° C

8 months