MAINTENANCE

5.04 Coolant Replacement Procedure

Replace coolant as follows:

1. Disconnect the system from main input power. At the bottom of the coolant tank, disconnect the coolant line

fitting and collect coolant in a disposable container.

2. Connect the system to main input power and turn it on to allow the pump to empty the tank,. The pump

will run approximately for 20 seconds before the flow switch causes an interlock. This procedure may be
repeated a few times until the tank is completely empty.

3. Connect the coolant line fitting and fill the tank with fresh coolant until the right level is reached.

RETURN

SUPPLY

RETURN

SUPPLY

Art # A-04803

COOLANT

Fill Range

Coolant Tank

4. Turn system on, let it run for a few minutes and check coolant level, refill if necessary.