Tweco 300 Auto-Cut Manuel d'utilisation

Page 18

Advertising
background image

Manual No. 0-4817 Auto-Cut 300

2-2

SPECIFICATIONS

2.06 Power Supply Specifications & Electrical Requirements

Max OCV (U

0

)

380 vdc

Max Output Current 300 Amps
Output Voltage

160 vdc

Duty Cycle Rating

100% @ 300A @ 180V (54kW)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.70 @ 100 ADC Output

Cooling

Forced Air (Class F)

Auto-Cut 300 Power Supply Specifications

Input

Power Input

Current

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

50/60

74

206

260

#3/0

2

230

50/60

72

181

230

#2

2

400

50/60

75

109

135

#3

1

400 (CE)

50/60

89

112

150

#2

1

460

50/60

89

112

150

#2

1

Auto-Cut 300 Power Supply Input Power Specifications

2

Extra Hard Usage Type G, G-GC, W

Suggested Sizes (See Note)

Line Voltages with Suggested Circuit Protection and Wire Sizes

1

Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW

Based on National Electric Code and Canadian Electrical Code

CAUTION

Fuse and wire sizes are for reference only. The installation must conform to national and local codes for
the type and method of wire being used.