Tweco 300 Auto-Cut Manuel d'utilisation

Page 102

Advertising
background image

Manual 0-4817 Auto-Cut 300

A-6

APPENDIX

Appendix 5: CNC - Control Module Board PCB Connections

Art # A-04900

TB1-1 E-Stop (Com)

TB1-2 E-Stop

TB1-3

TB1-4 Stop Latched

TB1-5 Start / Stop Ret

TB1-6 Start / Stop or Start Latched (NO)

TB1-7 Divided Arc Voltage (-)

TB1-8 Divided Arc Voltage (+)

TB1-9 Remote Analog Current Control (0-10V) (-)

TB1-10 Remote Analog Current Control (0-10V) (+)

TB1-11

TB1-12

TB2-1 Hold Start (-)

TB2-2 Hold Start (+)

TB2-3 Preflow On (-)

TB2-4 Preflow On (+)

TB2-5

TB2-6 Pilot On (Relay Contacts NO)

TB2-7

TB2-8 Pilot On (Relay Contacts NO)

TB2-9

TB2-10 OK to Move (Contacts or DC Volts) (-)

TB2-11

TB2-12 OK to Move (Contacts or DC Volts) (+)

TB2

TB1

Sustained Start / Stop

TB1-5

TB1-6

Momentary Start / Stop

TB1-4

TB1-5

TB1-6

Stop

Start

Start / Stop Circuit Configurations

These points are jumpered together at the factory.
Remove the jumper to use existing E-Stop circuits.