Cnc functions – Tweco 300 Auto-Cut Manuel d'utilisation

Page 103

Advertising
background image

Manual 0-4817 Auto-Cut 300

A-7

APPENDIX

CNC functions

CNC I/O circuits provide at least 1000V galvanic isolation from the plasma power supply.

While the CNC circuits are isolated from the power supply, many of the signal returns on J15 and TB1 & 2 are common
to each other. J15 pins 1, 4, 5 & 10 and TB1-1, 5, 7, 9, and TB2-1 & 3 are all common. J15 pin 12 and TB2-10 are also
connected to the others when SW6 (OK to Move select) is set for voltage.

Rear Panel CNC Connector J15:

14 Circuit (Amp CPC) Remote Standard:

Chassis gnd (for SC-11 cable shield)

1

1

Start/Stop

3 (+); 4 (-)

1

Ok to Move (contacts or voltage

2

)

12(-); 14 (+)

1

Divided Arc volts (selectable

ratio 50:1; 40:1; 30:1; 16.6:1)

5 (-); 6 (+)

Arc Volts (w/100K series res)

7 (-); 9 (+)

1

Analog Current Control (0-10V)

3

10 ( ); 11 ( )

Isolated Circuit Comm (for SC-11)

8

Chassis Gnd

13

1

These are also duplicated on TB1 & TB2, use one or the other not both. Additional functions are only available on TB1 & 2.

2

SW6 on CCM I/O PCB selects OK to Move for isolated contact closure or DC Volts (15-18V) at <100ma. When set for

contacts, OK to Move circuit is rated for 120 VAC / 28 VDC @ 1A.

Internal CNC connections. TB1 & TB2 on CCM module.

Connections are provided on the CCM module TB1 & TB2 terminal blocks including most of the rear panel functions
plus some additional features. All these signals are isolated from the plasma power supply but signals marked
(comm.) and (-) are common to each other.

Users are expected to install their own CNC cable to these connections. Knockout hole is provided in rear panel of CCM
module. User shall provide strain relief / cord grip for user installed cable.

Function

Connection

E-Stop

TB1-1 (comm.) & TB1-2

Stop Latched (NC)

4

TB1-4

Start/Stop Ret

4

TB1-5 (comm.)

Start /Stop or Start Latched (NO)

4

TB1-6

Divided Arc Voltage

TB1-7(-); TB1- 8(+)

Remote Analog Current Control (0-10V)

TB1-9(-); TB1-10(+)

Hold Start

TB2-1(-); TB2-2(+)

Preflow On

TB2-3(-); TB2-4(+)

Pilot On (Relay Contacts NO)

TB2-6; TB2-8

OK to Move (Contacts or DC Volts)

TB2-10(-); TB2-12(+)

Advertising