Manual No. 0-4817 Auto-Cut 300

4-7

OPERATION

4.05 System Operation

This section contains operating information which is specific to the power supply.

WARNINGS

Frequently review the safety precautions in Section 1.

Disconnect primary power at the source before assembling or disassembling power supply, torch parts,
or torch and leads assemblies, or adding coolant.

It is not enough to simply move the ON/OFF switch on the unit to OFF position when cutting operations
have been completed. Always open the power supply disconnect switch five minutes after the last cut
is made.

1. Connect system to primary input power.

2. Turn ON/OFF switch to ON (up) position. AC Lamp

turns ON. Fan and coolant pump turn on. There

is a start-up purge of gas through the system.

POWER

ON

OFF

O

I

OFF

O

Art # A-04842

3. Check the AC lamp. If lamp is ON, AC input power is present in the power supply.

Circuitry in the power supply monitors the status of various conditions. If the circuitry detects a situation
requiring operator attention, the status lamp on the control panel flashes a 2-part code to indicate a code group
and then a particular condition within the group. After 4 seconds, the sequence repeats.

Example: Lamp flashes 4 times; the condition is in group 4. After a 1.2 second delay, the lamp blinks 3 times;
the status code is 4-3. After a 4-second delay, the lamp repeats the sequence until the condition is corrected.

Some conditions can be active indefinitely, while others are momentary. The power supply latches momentary
conditions; some momentary errors can shut down the system. The lamp may show multiple conditions in
sequence; it is important to recognize all possible conditions that may be displayed. The Error Code section
provides explanations of status codes.