Section 3: installation, 01 installation requirements, Section 3: installation -1 – Tweco 300 Auto-Cut Manuel d'utilisation

Page 25: 01 installation requirements -1

Advertising
background image

Manual No. 0-4817 Auto-Cut 300

3-1

INSTALLATION

SECTION 3: INSTALLATION

3.01 Installation Requirements

Electric Supply

The electrical supply network, the gas and water supply system must meet local safety standards. This conformity
shall be checked by qualified personnel.

Input

Power Input

Current

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

50/60

74

206

260

#3/0

2

230

50/60

72

181

230

#2

2

400

50/60

75

109

135

#3

1

400 (CE)

50/60

89

112

150

#2

1

460

50/60

89

112

150

#2

1

Auto-Cut 300 Power Supply Input Power Specifications

2

Extra Hard Usage Type G, G-GC, W

Suggested Sizes (See Note)

Line Voltages with Suggested Circuit Protection and Wire Sizes

1

Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW

Based on National Electric Code and Canadian Electrical Code

CAUTION

Fuse and wire sizes are for reference only. The installation must conform to national and local codes for
the type and method of wire being used.

Gas Supply

The customer must supply all gases and pressure regulators. Gases must be of high quality. Pressure regulators
must be double-stage and installed as close as possible to the gas console. Contaminated gas can cause one or
more of the following problems:

• Reduced cutting speed

• Poor cut quality

• Poor cutting precision

• Reduced consumables life.

• Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.

Cooling System Requirements

Coolant must be added to the system on installation. The amount required varies with torch leads length.

Thermal Dynamics recommends the use of its coolants 7-3580 and 7-3581 (for low temperatures).

Cat. Number and Mixture

Mixture

Protects To

7-3580 'Extra-Cool

TM

'

25 / 75

10° F / -12° C

7-3581 'Ultra-Cool

TM

'

50 / 50

27° F / -33° C

7-3582 'Extreme Cool

T M

'

Concentrate*

-65° F / -51° C

Coolant Capabilities

* For mixing with D-I Cool

TM

7-3583