Tweco 300 Auto-Cut Manuel d'utilisation

Page 62

Advertising
background image

Manual No. 0-4817 Auto-Cut 300

4-10

OPERATION

Error

Code Error

Remedy / Comments

1-1

External E-Stop Activated
or
Plasma Enable Switch OFF

Check and correct.

1-2

Pilot Ignition Failure

Pilot does not start > 15 seconds.

1-3

Pilot Out

Pilot shut off without shutoff signal.

1-4

Loss of Transfer

Arc transferred (>50 ms) then shut off
without signal.

1-5

Off the Plate

Torch moved past edge of metal (0nly with Off Plate
enabled and Auto Pilot Restart disabled.)

1-6

Transfer Timeout (Failure to
transfer in allowed time)

Must transfer from pilot to cutting arc
in 85 ms. (Sw 8-1 off) or 3 sec (SW 8-1 on).

1-7

Tip Saver

(If enabled; active during ramping and cutting.
Possible double arc.

1-8

Shorted Torch

Electrode to tip voltage <50v
w/ inverter on.

2-1

Missing Phase

1 of 3 input AC phases missing.

2-2

Input voltage out of tolerance Test and correct.

2-3

Power Supply Overheated

Inverter module or pilot module overheated.

2-4

Power Supply Not ready

2-5

DC Output Low

< 60 vdc.

2-6

AC Input over Current Fault

Turn off power to reset.

2-7

Unwanted Current

Possible shorted torch. Current in pilot lead or work
lead before pilot arc starts.

2-8

Unwanted Pilot
Current Signal

Current in pilot circuit before starting pilot.

2-9

Unwanted Transfer

Current in work lead before
starting pilot.

Fault Code Key

Note

These codes are for systems with Firmware versions 2.4 or later. If your system’s Firmware is a prior
version, contact your distributor for updates.