Installation continued – Garland G2000 SERIES GAS BAKE AND ROAST DECK OVENS Manuel d'utilisation
Page 8

Part # P125 Rev 2 (07/31/12)
Page 8
INSTALLATION Continued
The flue deflector provided (Fig. 1) should be installed
to prevent this situation from occurring. Set the flue
deflector in place over the flanges of the internal flue. The
sloped opening of the flue deflector will be to the front.
Fasten the side flanges of the flue deflector by means of
the sheet metal screws provided.
2. If the oven must be connected to a direct flue, this flue
should rise 10 feet above the roof of the building in
which the oven is installed, or 10 feet above any portion
of a building within a horizontal distance of 10 feet. The
draft hood provided must be installed. In addition, it is
necessary that barometric draft control (available from
Garland) be installed. (See Fig. 2)
The draft hood should be positioned with its vertical
bottom opening over the vertical flanges of the oven
flue. The flanges of the draft hood should be to the sides
and front. Fasten the draft hood to the oven by means of
sheet metal screws through the holes on each side flange
at the bottom of the draft hood.
The barometric damper must be installed to conform
with the applicable instructions packed with the
barometric damper. The relief opening of the barometric
damper should be located so that it is not obstructed by
any part of the oven or adjacent constructions.
The barometric damper should be installed as close to
the draft hood as possible, while conforming to code
requirements.
Under no circumstances should flue pipe with less than
a 6 inch diameter be installed between the oven and the
chimney termination.
If more than one appliance is connected to a single
vent, the vent shall be sized in accordance with sound
engineering principles.
FLUE DEFLECTOR
FIGURE 1
BAROMETRIC
DAMPER
DRAFT HOOD
FIGURE 2
Top Trim Installation
The front of the top trim is formed as a channel. Open the
upper oven door. Hold the top trim with the rear raised
and slide its lower flange into position in the oven opening
between the right and the left front columns. Lower the top
trim into position over the oven top. The top trim does not
require that it be bolted or fastened into position.
Ovens with Optional Light Feature
Important: This appliance must be electrically grounded in
accordance with local codes, or in the absence of local codes,
the Canadian Electrical Code C22.1 or with the National
electrical code ANSI/NFPA No. 70 (latest edition whichever is
applicable.
Warning – Electric Grounding Instructions
This appliance is equipped with a three prong (grounding)
plug for your protection against shock hazard and must be
plugged into a properly grounded three prong receptacle.
Do not cut or remove the grounding prong from this plug.
A wiring diagram is attached to the back of the unit.
Gas Connection-Single & Multiple Ovens
Single Oven
Install the pressure regulator (supplied) with the outlet
(arrowhead) connected to the tail pipe. The ¾” N.P.T. inlet of
the pressure regulator must be considered in piping the gas
supply. Each group of ovens should be supplied (by others)
with an in-line manual shut off valve.