INSTALLATION Continued

The flue deflector provided (Fig. 1) should be installed

to prevent this situation from occurring. Set the flue

deflector in place over the flanges of the internal flue. The

sloped opening of the flue deflector will be to the front.

Fasten the side flanges of the flue deflector by means of

the sheet metal screws provided.

2. If the oven must be connected to a direct flue, this flue

should rise 10 feet above the roof of the building in

which the oven is installed, or 10 feet above any portion

of a building within a horizontal distance of 10 feet. The

draft hood provided must be installed. In addition, it is

necessary that barometric draft control (available from

Garland) be installed. (See Fig. 2)

The draft hood should be positioned with its vertical

bottom opening over the vertical flanges of the oven

flue. The flanges of the draft hood should be to the sides

and front. Fasten the draft hood to the oven by means of

sheet metal screws through the holes on each side flange

at the bottom of the draft hood.

The barometric damper must be installed to conform

with the applicable instructions packed with the

barometric damper. The relief opening of the barometric

damper should be located so that it is not obstructed by

any part of the oven or adjacent constructions.

The barometric damper should be installed as close to

the draft hood as possible, while conforming to code

requirements.

Under no circumstances should flue pipe with less than

a 6 inch diameter be installed between the oven and the

chimney termination.

If more than one appliance is connected to a single

vent, the vent shall be sized in accordance with sound

engineering principles.

FLUE DEFLECTOR

FIGURE 1

BAROMETRIC

DAMPER

DRAFT HOOD

FIGURE 2

Top Trim Installation

The front of the top trim is formed as a channel. Open the

upper oven door. Hold the top trim with the rear raised

and slide its lower flange into position in the oven opening

between the right and the left front columns. Lower the top

trim into position over the oven top. The top trim does not

require that it be bolted or fastened into position.

Ovens with Optional Light Feature

Important: This appliance must be electrically grounded in

accordance with local codes, or in the absence of local codes,

the Canadian Electrical Code C22.1 or with the National

electrical code ANSI/NFPA No. 70 (latest edition whichever is

applicable.

Warning – Electric Grounding Instructions

This appliance is equipped with a three prong (grounding)

plug for your protection against shock hazard and must be

plugged into a properly grounded three prong receptacle.

Do not cut or remove the grounding prong from this plug.

A wiring diagram is attached to the back of the unit.

Gas Connection-Single & Multiple Ovens

Single Oven

Install the pressure regulator (supplied) with the outlet

(arrowhead) connected to the tail pipe. The ¾” N.P.T. inlet of

the pressure regulator must be considered in piping the gas

supply. Each group of ovens should be supplied (by others)

with an in-line manual shut off valve.