Installation Instructions
Section 2
9
Maximum Breaker Size & Minimum Circuit Amperage Chart
QUIETQUBE REMOTE CONDENSING UNIT
Important
Due to continuous improvements, this information is for reference only.
Please refer to the ice machine serial number tag to verify electrical data.
Serial tag information overrides information listed on this page.
Series Ice
Machine
Voltage
Phase
Cycle
Air-Cooled
Water-Cooled
QuietQube
Max
Fuse/
Circuit
Breaker
Min
Circuit
Amps
Total
Circuit
Amps
Max
Fuse/
Circuit
Breaker
Min
Circuit
Amps
Max
Fuse/
Circuit
Breaker
Total
Circuit
Amps
RF0244
115/1/60
15 Amp
N/A
7.5
N/A
N/A
—
—
230/1/50
10 Amp
N/A
0.87
N/A
N/A
—
—
RF0266
115/1/60
15 Amp
N/A
7.5
N/A
N/A
—
—
230/1/50
10 Amp
N/A
0.87
N/A
N/A
—
—
RF0385
115/1/60
15 Amp
N/A
10.0
N/A
N/A
—
—
230/1/50
N/A
N/A
N/A
N/A
N/A
—
—
RF0388
115/1/60
15 Amp
N/A
10.0
N/A
N/A
—
—
230/1/50
10 Amp
N/A
2.9
N/A
N/A
—
—
RF0399
115/1/60
15 Amp
N/A
10.0
N/A
N/A
—
—
230/1/50
10 Amp
N/A
2.9
N/A
N/A
—
—
RF0644
115/1/60
25 Amp
N/A
13.5
N/A
N/A
—
—
RFS0300
115/1/60
20 Amp
12.8
N/A
N/A
N/A
—
—
RFS0650
115/60/1
25 Amp
16.3
N/A
25 Amp
15.4
—
—
208-230/1/60
15 Amp
8.7
N/A
15 Amp
8.2
—
—
RF1200
208-230/1/60
15 Amp
15.0
N/A
15 Amp
15.0
15 Amp
1.4
230/1/50
16 Amp
7.3
N/A
16 Amp
7.3
10 Amp
1.4
RF2300
208-230/3/60
20 Amp
15.0
N/A
20 Amp
15.0
15 Amp
3.2
400-415/3/50
16 Amp
13.9
N/A
16 Amp
13.9
10 Amp
3.2
RF1200R
208-230/1/60
15 Amp
1.4
N/A
N/A
N/A
—
—
RF2300R
208-230/3/60
15 Amp
3.2
N/A
N/A
N/A
—
—
Maximum allowable voltage variation at compressor start-up is ±10% of voltage listed above and on the model/serial plate.
Condensing Unit
Voltage Phase Cycle
Maximum Fuse/Circuit Breaker
Minimum Circuit Amps
RCU1075
208-230/60/1
15
15
208-230/60/3
15
15
208-230/50/1
15
15
RCU2375
208-230/60/1
15
15
208-230/60/3
15
15
208-230/50/1
15
15