RFS0300 Operation

The ice machine will not start until:

A. The rocker switch is moved to “ON”.

B. Ice does not contact the bin thermostat bulb.

C. The water reservoir is full of water.

Placing the toggle switch in the ON position starts the
gear motor and a 10 minute compressor time delay. The
compressor starts and the float valve controls the water
inlet valve and water level. The freeze cycle ends when
ice contacts the bin thermostat. The ice machine remains
off until ice no longer contacts the bin thermostat.

RFS0650/RF1200/RF2300 Operation

The ice machine will not start until:

A. The rocker switch is moved to “ON”.

B. Ice does not contact the bin thermostat bulb.

C. The water reservoir is full of water.

Placing the toggle switch in the ON position starts the
gear motor. After the rotation speed sensor verifies
10 minutes of correct rotation, the time delay ends and
the compressor starts. The ice machine will continue to
make ice until ice contacts the bin thermostat. The ice
machine remains off until ice no longer contacts the bin
thermostat.