NOTE: Flake ice machines use an auger to remove ice from the evaporator. Occasional noises (creaks, groans,
squeaks, or pops) are a normal part of the ice making process.

Evaporator Low Temperature Safety
Thermostat and Bin Thermostat

The bin thermostat sensing bulb is located in the ice
chute or bin and turns the ice machine on and off as the
level of ice in the ice chute or bin changes.

RF0244/RF0266/RF0385/

RF0388/RF0399/RF0644 Operation

The ice machine will not start until:

A. The rocker switch is moved to “ON”.

B. Ice does not contact the bin thermostat bulb.

C. The water reservoir is full of water.

Placing the toggle switch in the ON position starts the
gear motor and refrigeration system. The float valve
controls the water inlet valve and water level. The freeze
cycle ends when ice contacts the bin thermostat. The ice
machine will restart when ice no longer contacts the bin
thermostat.

Model

Bin

Thermostat

Setting

Evaporator

Thermostat

Setting

RF0244/RF0266

5

5

RF0388/RF0399/

RF0644

5

7

RFS0300

4

7

RFS0650

4

N/A

RF1200/RF2300

5

N/A

1

2

3

4

5

6

7

1

2

3

4

5

6

7

BIN THERMOSTAT

SMALL NUMBERS = LESS ICE IN BIN

LARGE NUMBERS = MORE ICE IN BIN

EVAPORATOR LOW TEMPERATURE

SAFETY THERMOSTAT

INCORRECT SETTINGS WILL CAUSE ICE

MACHINE TO SHUT OFF

SENSING BULB IS

LOCATED IN BIN

BIN THERMOSTAT

LOCATION

EVAPORATOR LOW

TEMPERATURE SAFETY

THERMOSTAT LOCATION