Removal of Parts for Cleaning/Sanitizing

1. Turn off the water supply to the ice machine at the

water service valve.

2. Remove the components listed on the following

pages for cleaning and sanitizing.

3. Soak the removed part(s) in a properly mixed

solution of cleaner and water.

4. Use a soft-bristle brush or sponge (NOT a wire

brush) to carefully clean the parts.

5. Use the solution and a brush or sponge to clean all

disassembled components and the inside of the bin.

6. Rinse all cleaned parts with clear water.

7. Mix a solution of sanitizer and water.

8. Soak the parts in the sanitizer/water solution for

10 minutes. Use the sanitizer/water solution and a
sponge to sanitize all removed components and the
inside of the bin. Do not rinse the sanitized parts.

9. Continue with step 11 of the cleaning/sanitizing

procedure.

ICE CHUTE REMOVAL

RFS0300/RFS0650/RF1200/RF2300 Only

1. Place the toggle switch in the OFF position, turn off

the water supply and disconnect electrical power to
the ice machine.

2. Disconnect water supply.

3. Remove water reservoir cover.

4. Remove microswitch and bin thermostat from the ice

chute.

5. Remove retainer, ice chute elbow and ice chute.

!

Warning

Disconnect electric power to the ice machine at the
electric switch box and wear rubber gloves and
safety goggles (or face shield) while handling
cleaner or sanitizer.

! Caution

Do not mix Cleaner and Sanitizer solutions together.
It is a violation of Federal law to use these solutions
in a manner inconsistent with their labeling.

Solution Type

Water

Mixed With

Cleaner

1 gal. (4 L)

16 oz (500 ml) cleaner

Part Number 000000084

Solution Type

Water

Mixed With

Sanitizer

3 gal. (11 L)

2 oz (60 ml) sanitizer

Part Number 94-0565-3