Section 4 maintenance, Interior cleaning and sanitizing, Cleaning/sanitizing procedure – Manitowoc Ice RF Manuel d'utilisation

Page 19: Heavily scaled cleaning procedure, Exterior cleaning, Section 4, Maintenance

Advertising
background image

21

Part Number 000007644 3/11

Section 4

Maintenance

Interior Cleaning and Sanitizing

Maintenance procedures covered in this manual are not
covered by the warranty.

CLEANING/SANITIZING PROCEDURE

This procedure must be performed once every month.

All ice must be removed from the bin.

The ice machine and bin must be disassembled
cleaned and sanitized.

The ice machine produces ice with the cleaner and
sanitizer solutions.

All ice produced during the cleaning and sanitizing
procedure must be discarded.

HEAVILY SCALED CLEANING PROCEDURE

Perform this procedure if you have some or all of these
symptoms.

Grinding, popping or squealing noises from the
evaporator.

Grinding noise from gearbox.

Ice machine trips speed sensor.

NOTE: A Cleaning/Sanitizing Procedure must be
performed after this procedure.

Exterior Cleaning

Remove dust and dirt off exterior surfaces with mild
household dishwashing detergent and warm water. Wipe
dry with a clean, soft cloth.

Cleaning/Sanitizing Procedure

Use Nickel Safe Ice Machine Cleaner, part number
000000084.

Use Ice Machine Sanitizer part number 94-0565-3.

Step 1 Remove front and top covers and set the toggle
switch to the OFF position.

Step 2 Remove all ice from the bin.

Step 3 Turn off the ice making water supply and drain
water from evaporator and reservoir.

Step 4 Remove the top cover from water reservoir.

Step 5 Follow the chart and premix cleaner and water.

Step 6 Fill the evaporator and reservoir with cleaning
solution.

Step 7 Move the toggle switch to the ON position. The
ice machine will make ice with the cleaning solution and
deposit the ice in the bin. Add the remaining cleaner/
water solution as the water level in the reservoir drops.

NOTE: Do not allow the cleaner/water level to drop
below the minimum water level. The ice machine will
discontinue the cleaning cycle if the water float switch
opens.

Step 8 After all of the cleaner/water solution has been
added, turn on the ice making water supply. Continue
the freeze cycle for 10 minutes to remove the cleaning
solution from the water circuit.

Step 9 Place the toggle switch in the OFF position.

! Caution

Use only Manitowoc approved Nickel Safe Ice
Machine Cleaner (part number 000000084) and
Sanitizer (part number 94-0565-3). Do not mix
Cleaner and Sanitizer solutions together. It is a
violation of Federal law to use these solutions in a
manner inconsistent with their labeling. Read and
understand all labels printed on bottles before use.

!

Warning

Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or
Sanitizer.

Amount of Water

Amount of Nickel Safe
Cleaner - Part Number

000000084

1 gallon (4 Liters)

3 ounces (90 ml)

Advertising