Installation Instructions

Part Number 000007644 3/11

10

Refrigeration System Installation

Remote Condensing Unit Only

USAGE WITH NON-MANITOWOC

CONDENSING UNITS

Manitowoc Remote Condensing Units are specifically
designed for usage with a QuietQube® Ice Machine
Head Section. Standard condensing units and Non-
Manitowoc condensing units are not approved for use
with a QuietQube® Ice Machine Head Section.

Factory Equipment Refrigeration Amounts

ICE MACHINE HEAD SECTION

Each ice machine condensing unit ships from the factory
with a R-404A refrigerant charge appropriate for the
entire system operation. The serial tag on the ice
machine indicates the refrigerant charge. The refrigerant
charge is sufficient to operate the ice machine in
ambient temperatures between -20°F (-28.9°C) and
120°F (48.9°C). With line set lengths of up to 100 feet
(30.5 m).

REFRIGERATION LINE SETS/TRAP KIT

Refrigeration Rated Tubing and Trap Kits are shipped
capped with atmospheric pressure.

QuietQube®

Ice Machine

Remote

Condensing Unit

Line Set*

RF1200C
RF2300C

RCU1075C
RCU2375C

RC-21
RC-31
RC-51

*Line Set

Suction Line

Liquid Line

RC 21/31/51

5/8 inch

(15.9 mm)

3/8 inch

(9.5 mm)

Important

Manitowoc remote systems are only approved and
warranted as a complete new package. Warranty on
the refrigeration system will be void if a new ice
machine head section is connected to pre-existing
(used) tubing or condensing units or vice versa.

! Caution

The 60-month compressor warranty (including the 24-
month labor replacement warranty) will not apply if the
Manitowoc Ice Machine and Manitowoc Remote
Condensing Unit are not installed according to
specifications. This warranty also will not apply if the
refrigeration system is modified with a condenser,
heat reclaim device, or other parts or assemblies not
manufactured by Manitowoc Ice.

!

Warning

Potential Personal Injury Situation

The QuietQube Condensing Unit contains the
refrigerant charge. Installation and brazing of the line
sets must be performed by a properly trained and
EPA certified refrigeration technician aware of the
dangers of dealing with refrigerant charged
equipment.

! Caution

Never add more than nameplate charge to the
refrigeration system for any application.

!

Warning

Installation of a QuietQube® Condensing Unit may
require the use of special equipment for placement.
Trained and qualified personnel are required for
proper rigging and lifting.

Advertising