Installation Instructions

Section 2

7

Part Number 000007644 3/11

Water and Drain Requirements

POTABLE WATER REQUIREMENTS

Follow these guidelines to install water inlet lines:

Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on sink
faucets, dishwashers, etc.)

If water pressure exceeds the maximum of 80 psig
(552 kPA) recommended pressure, obtain a water
pressure regulator from your Manitowoc distributor.

Install a water shut-off valve and union for both the
ice making and condenser water lines.

Insulate water inlet lines to prevent condensation.

Plumbing must conform to local codes.

WATER SUPPLY AND DRAIN LINE SIZING/
CONNECTIONS

Typical Water Supply Drain Installation

DRAIN CONNECTIONS

Follow these guidelines when installing drain lines to prevent
drain water from flowing back into the ice machine and storage
bin:

Drain lines must have a 1.5 inch drop per 5 feet of run (2.5
cm per meter), and must not create traps.

The floor drain must be large enough to accommodate
drainage from all drains.

Run separate bin and water-cooled condenser drain lines.
Insulate them to prevent condensation.

Vent the bin and ice machine drain to the atmosphere. The
ice machine drain requires an 18" (46 cm) vent. Do not
vent the condenser drain on water-cooled models.

Drains must have a union or other suitable means to allow
in place disconnection from the ice machine when
servicing is required.

Location

Water Temp

Min/Max

Water

Pressure

Min/Max

Fitting/Min

Tubing

Size

Potable

Water Inlet

40°/90°F

(4°/32°C)

14/80 psi

(100/552 kPA)

3/8" FPT

Potable

Water Drain

---

---

1/2" MPT

Condenser

Water Inlet

40°/90°F

(4°/32°C)

20/150 psi

(138/1034 kPA)

3/8” FPT

RF2300 only

= 1/2" FPT

Condenser

Water Drain

---

---

1/2" MPT

Bin Drain

---

---

3/4" FPT

Large Capacity Bin Drain

---

1" FPT

VENT TUBE

18" (46 CM)

LONG

ROUTE

DRAIN

TUBING TO

OPEN SITE

DRAIN

ICE MAKING

WATER INLET

TUBING 3/8" MIN.

I.D. (.95 CM)

VENT TUBE

18" (46 CM)

LONG

SEPERATE BIN AND ICE

MACHINE DRAINS ARE

REQUIRED

ROUTE DRAIN TUBING TO

OPEN SITE DRAIN

WATER SHUT-OFF VALVE

REQUIRED - ICE MAKING

WATER INLET TUBING 3/8"

MIN. I.D. (.95 CM)