Installation

5

Oven Location and Ventilation

LOCATION
The well planned and proper placement of your

oven will result in long term operator convenience

and satisfactory performance.
The following clearances must be maintained be-

tween the oven and any combustible or non-com-

bustible construction.

D

Oven body sides --- 20” (58.8cm)

D

Oven body back ---0” (0cm)

The following clearances must be available for ser-

vicing.

D

Oven body sides --- 38” (96.5cm)

D

Oven body back --- 28” (71cm)

NOTE: On gas models, routine servicing can usu-

ally be accomplished within the limited

movement provided by the gas hose re-

straint. If the oven needs to be moved fur-

ther from the wall, the gas must first be

turned off and disconnected from the oven

before removing the restraint. Reconnect

the restraint after the oven has been re-

turned to its regular position.

It is essential that an adequate air supply to the

oven be maintained to provide a sufficient flow of

combustion and ventilation air.

D

Place the oven in an area that is free of drafts.

D

Keep the oven area free and clear of all combus-

tibles such as paper, cardboard, and flammable

liquids and solvents.

D

Do not place the oven on a curb base or seal to

a wall. This will restrict the flow of air and prevent

proper ventilation to the blower motors. This

condition must be corrected to prevent perma-

nent damage to the oven.

VENTILATION
On gas models the necessity for a properly de-

signed and installed ventilation system cannot be

over emphasized. This system allows the oven to

function properly while removing unwanted va-

pors and products of combustion from the operat-

ing area.
This oven must be vented with a properly de-

signed mechanically driven exhaust hood. The

hood should be sized to completely cover the

equipment plus an overhang of at least 6” (15cm)

on all sides not adjacent to a wall. The distance

from the floor to the lower edge of the hood should

not exceed 7’ (2.1m). The capacity of the hood

should be sized appropriately and provisions

should be made for adequate makeup air.
U.S. and Canadian installations
Refer to your local ventilation codes. In the ab-

sence of local codes, refer to the

National ventila-

tion code titled, “Standard for the Installation of

Equipment for the Removal of Smoke and Grease

Laden Vapors from Commercial Cooking Equip-

ment”, NFPA-96-Latest Edition.
Australia and general export installations
Installation must conform with Local and National

installation standards. Local installation codes

and/or requirements may vary. If you have any

questions regarding the proper installation and/or

operation of your Blodgett oven, please contact

your local distributor. If you do not have a local dis-

tributor, please call the Blodgett Oven Company at

0011-802-860-3700.

WARNING:
Failure to properly vent the oven can be

hazardous to the health of the operator

and may result in operational problems,

unsatisfactory baking and possible dam-

age to the equipment.
Damage sustained as a direct result of im-

proper ventilation will not be covered by

the Manufacturer’s warranty.