Installation

13

Gas Connection

GAS HOSE RESTRAINT
If the oven is mounted on casters, a commercial

flexible connector with a minimum of 3/4” (1.9 cm)

inside diameter must be used along with a quick

connect device.
The restraint, supplied with the oven, must be

used to limit the movement of the unit so that no

strain is placed upon the flexible connector. The

restraint should be fastened to the base frame of

the oven as close to the flexible connector as pos-

sible. It should be short enough to prevent any

strain on the connector. With the restraint fully

stretched the connector should be easy to install

and quick connect.
The restraint (ie: heavy gauge cable) should be at-

tached without damaging the building. DO NOT

use the gas piping or electrical conduit for the at-

tachment of the permanent end of the restraint!

Use anchor bolts in concrete or cement block. On

wooden walls, drive hi test wood lag screws into

the studs of the wall.

WARNING!!
If the restraint is disconnected for any

reason it must be reconnected when the

oven is returned to its original position.

U.S. and Canadian installations
The connector must comply with the

Standard for

Connectors for Movable Gas Appliances, ANSI

Z21.69 or Connectors For Moveable Gas Ap-

pliances CAN/CGA-6.16 and a quick disconnect

device that complies with the

Standard for Quick-

Disconnect Devices for Use With Gas Fuel, ANSI

Z21.41 or Quick Disconnect For Use With Gas Fuel

CAN 1-6.9. Adequate means must be provided to

limit the movement of the appliance without de-

pending on the connection and the quick discon-

nect device or its associated piping.
A drip leg must be used at each appliance. Refer

to

NFPA54/ANSI Z223.1 - Latest Edition (National

Fuel Gas Code) for proper drip leg installation.
Australia and general export installations
The restraint and quick connect must conform

with Local and National installation standards. Lo-

cal installation codes and/or requirements may

vary. If you have any questions regarding the prop-

er installation and/or operation of your Blodgett

oven, please contact your local distributor. If you

do not have a local distributor, please call the

Blodgett Oven Company at 0011-802-860-3700.

Tighten after

adjustment

(See VIEW A)

VIEW A

Gas

Hose

Socket

Quick Connect

Socket

Plug

IMPORTANT:

Cable restraint should be fas-

tened as close as possible to flex-

ible connector and short enough

to prevent any strain on flexible

connect. At maximum stretch of

shortened restraint the flexible

connector should be easy to in-

stall and quick connect.

Gas

Supply Line

Attachment Plate

(2 supplied)

1 for wall mount

1 for leg bolt

Note: fastener for wall

mount not supplied

Attachment Plate

(secure with leg

mount bolt)

Installation of Gas Hose and Restraint

Figure 14