Installation, Electrical connection – Blodgett MT3855G-G Manuel d'utilisation

Page 18

Advertising
background image

Installation

14

Electrical Connection

Before making any electrical connections to this

unit, check that the power supply is adequate for

the voltage, amperage, and phase requirements

stated on the rating plate.
NOTE: The rating plate is located on the control

box.

A wiring diagram accompanies this manual and is

also attached inside the control box.
U.S. and Canadian installations
The MT3855 requires a 15 Amp, 60HZ, 1Φ,

208-240VAC, 4 wire service consisting of L1, L2,

neutral and ground. Use 90_C wire and size to Na-

tional Electric or local codes.
Single phase units MUST NOT be connected to

the high leg of a three phase system. The high leg

refers to a potential of 240 volts between one

phase and neutral. The remaining two legs have

a potential of 120 volts between each phase and

neutral.
Connect the four wires at the connections box lo-

cated on the lower left side of the control panel
1. Connect the two black wires to the 208-240

volt power source.

2. Connect the white wire to the system neutral.
3. Connect the green wire to the system ground.
Australia and general export installations
The MT3855 requires a 15 Amp, 50Hz, 1Φ,

220-240 VAC, 3 wire service consisting of L1, neu-

tral and ground. Use 90_C wire and size wire ac-

cording to local codes.

WARNING!!
Incorrect single phase wiring will result in

extensive damage to electrical compo-

nents and possible fire in the control box.

U.S. and Canadian Installations

L1
N
L2

120

120

208-240

Oven

Supply

General Export Installations

L1
N

220-240

Oven

Supply

Figure 15

THE BLODGETT OVEN COMPANY CANNOT AS-

SUME RESPONSIBILITY FOR LOSS OR DAMAGE

SUFFERED AS A RESULT OF IMPROPER INSTAL-

LATION.

Advertising