MAINTENANCE CHART

MAINTENANCE

NOTES:

• Severe or high cycle usage will require more frequent maintenance checks.

• Limits may have to be reset after any major operator adjustments.

• If lubricating chain, use only lithium spray. Never use grease or silicone spray.

• It is suggested that while at the site voltage readings be taken at the operator.

Using a digital voltmeter, verify that the incoming voltage to the operator it is

within ten percent of the operator’s rating.

Disconnect all power to the operator before servicing. ALWAYS disconnect the batteries to service the operator.

MAINTENANCE CHART

DESCRIPTION

TASK

CHECK AT LEAST ONCE EVERY

MONTH

6 MONTHS

Entrapment Protection Devices

Check and test for proper operation

X

Warning Signs

Make sure they are present

X

Manual Disconnect

Check and test for proper operation

X

Drive Chain and Pulley

Check for excessive slack and lubricate

X

Gate

Inspect for wear or damage

X

Accessories

Check all for proper operation

X

Electrical

Inspect all wire connections

X

Mounting Bolts

Check for tightness

X

Operator

Inspect for wear or damage

X