ADJUSTMENT

FUNCTIONALITY SWITCHES

M N

L2T

L T

0

17

26

10 11 E1 1

2 3P 5

7

2 C1 C3 C7 C8 TS

+ E

-

FC FA F

L NE FUSE

230V=1 6A F

120V=3 15A F

MOTOR FUSE

BX243=8A F

BX246=10A F

ACCESSORIES

FUSE

1 6A F

C BOARD

FUSE

1A F

+

RUN S

- +

SLOW S

- +

RUN V

-

+

SLOW V

-

+

A C T

-

+

PAR OP

-

ZN5U5

ZN5

CONTROL BOARD

PWR

1

C1

C3

C7

C8

ON

2

1

3

4

5

6

7

8

9 10

PROG

M N

L2T

L1T

L N

0

17

26

10 11 E1 1

2 3P 5

7

2 C1 C3 C7 C8 TS

+ E

-

FC FA F

         

/.

ON

OFF

Default Setting

FUNCTIONALITY SWITCHES

SWITCH

SETTING

FUNCTION

1

ON

Automatic Closing - The automatic close timer (ACT) is activated when the gate is open. The pre-set time is adjustable, depending of the

activation of any safety devices, and does not activate after a total safety “stop” or during a blackout.

2

ON

“Open-stop-close-stop” function with [2-7] command button and remote control (if a radio frequency card is installed).

OFF

“Open-close” function with [2-7] command button and remote control (if a radio frequency card is installed).

3

ON

“Open only” function with [2-7] command button and remote control (if a radio frequency card is installed).

4

OFF

Not used. Leave OFF.

5

OFF

With BX-243 motor.

ON

With BX-246 motor.

6

ON

Maintained action - The gate activates with constant pressure from command button (one 2-3P opening button, and one 2-7 closing button).

7

ON

Functioning of the photoelectric sensors’ safety test - Allows the card to check the efficiency of any safety devices (i.e. photoelectric sensors)

after every opening or closing command.

8

OFF

Total stop - This function stops the gate and then excludes any automatic closing cycle; to set in motion again, use either the keypad or

transmitter. Insert the safety device in [1-2]; If unused, set DIP switch to ON.

9

OFF

OPENING DURING CLOSING - If the photoelectric sensors detect an obstacle while the gate is closing, the gate reverses until fully opened;

connect the safety device to terminals [2-C1]; if unused, set DIP switch to ON.

10

OFF

PARTIAL STOP - Gate stops when an obstacle is detected by the safety device; once the obstacle is removed, the gate remains still or closes

if automatic closing is activated. Connect the safety device to terminal [2-C3]; if unused, set the DIP switch to ON.