20

ACCESSORY POWER + COMMAND AND CONTROL DEVICES +

WARNING DEVICES

OPTIONAL WIRING

ACCESSORY POWER

Command devices and accessories are 24V power. The overall power for accessories

CANNOT exceed 1.5 Amps.
Terminals 10 and 11 provide power for the following accessories:
• 24 Vac normally

COMMAND AND CONTROL DEVICES

Stop button (N.C. contact)
• Cancels automatic closing (A.C.T.). To resume normal operation, press the

command button or the remote control button. To disable this function set the

number 8 functionality switch to ON.

Key selector and/or partial opening button (N.O. contact)
• Partial gate opening

Key selector and/or command button (N.O. contact)
• Gate opening and closing command.
• By pressing the button or turning the key, the gate reverses direction or stops

depending on the functionality switch settings.

WARNING DEVICES

Open-gate indicator light
• Signals that gate is open; turns off when the gate is closed.
• Contact power: 24V A.C. - 25W maximum
• Socket rating 24V-3W maximum

NOTE: If the operator detects an obstacle in the same direction twice while running,

the electronic card activates the warning device and blocks the signal from the

remote control for 5 minutes. After 5 minutes, the alarm is deactivated and the

signal for the remote controls are restored and the PROG LED goes off. To restore

normal operation prior to the 5 minutes, press the total stop key and the PROG LED

goes off.

  %   0 



 # # # # 43

+ -

Cable lug with bolt and washer to secure to ground

  %   0 



 # # # # 43

  %   0 



 # # # # 43

Warning Device (Siren)

To protect against fire and electrocution:
• DISCONNECT power BEFORE installing or servicing operator.