Installation, Determine opening direction of gate – Controlled Products Systems Group BX-243C Manuel d'utilisation

Page 17

Advertising
background image

16

DETERMINE OPENING DIRECTION OF GATE

MOTOR AND LIMIT SWITCHES (OPEN TO THE LEFT)

The operator is factory configured for a left-handed installation.

- .

%

&# &! &

MOTOR AND LIMIT SWITCHES (OPEN TO THE RIGHT)

To change to a right-hand installation, reverse the wiring for the motor (M-N) and

limit switches (FA-FC).

- .

%

&# &! &

COM

NC

NC

COM

Red

Orange

White

Green

Left-handed (factory default)

24V (AC) motor with encoder

Close limit switch

Open limit switch

Orange

White

Brown

Green

Red

COM

NC

NC

COM

White

Red

Green

Red

Right-handed

24V (AC) motor with encoder

INSTALLATION

DETERMINE OPENING DIRECTION OF GATE

LEFT-HAND

RIGHT-HAND

Advertising