INSTALLATION

MANUAL RELEASE + ADJUST THE LIMITS

MANUAL RELEASE

1

Insert the key and turn it counter-clockwise. Open the release door and pull

the release lever.

ADJUST THE LIMITS

The operator is factory configured for a left-handed installation. To change to a

right-hand installation, reverse the wiring for the motor (M-N) and limit switches (FA-

FC) on the electronic card (ZN5/ZN5U), see page 16 for a wiring diagram.

OPEN LIMIT

1

Manually release the operator and fully open the gate.

2

Loosen the screw on the white cam.

3

Slide the white cam clockwise until it makes contact with the limit switch.

4

Tighten the screw on the white cam to lock the adjustment.

CLOSE LIMIT

1

Manually release the operator and fully close the gate.

2

Loosen the screw on the red cam.

3

Slide the red cam counter-clockwise until it makes contact with the limit switch.

4

Tighten the screw on the red cam to lock the adjustment.

Limit switch

White cam

Red cam

Limit switch

Open Limit

Close Limit