Introduction specifications – Empire Comfort Systems DV-55E-5 Manuel d'utilisation

Page 6

Advertising
background image

19563-4-0610

Page 6

Introduction

Always consult your local Building Department regarding

regulations, codes or ordinances which apply to the installation of

a direct vent wall furnace.
Instructions to Installer

1. Installer must leave instruction manual with owner after

installation.

2. Installer must have owner fill out and mail warranty card supplied

with furnace.

3. Installer should show owner how to start and operate furnace

and thermostat.

4. Installer must locate unit near a grounded wall receptacle for

115VAC power and must provide gas supply and vent the unit

properly for safe operation.

Warning:

Any change to this furnace or its control can be dangerous.

This is a heating appliance and any panel, door or guard

removed for servicing an appliance must be replaced prior

to operating the appliance.

General Information

This series is design certified in accordance with American National

Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian

Standards Association as a Fan Type Direct Vent Wall Furnace to

be installed according to these instructions.
Any alteration of the original design, installed other than

as shown in these instructions or use with a type of gas not

shown on the rating plate is the responsibility of the person and

company making the change.
Important

All correspondence should refer to complete Model Number, Serial

Number and type of gas.
Notice: During initial firing of this unit, oil from the heat exchanger

may bake out and smoke may occur. To prevent triggering of smoke

alarms, ventilate the room in which the unit is installed.
Installation in Residential Garages

Gas utilization equipment in residential garages shall be installed

so that all burners and burner ignition devices are located not less

than 18" (457mm) above the floor.

Such equipment shall be located, or protected, so it is not subject

to physical damage by a moving vehicle.
Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment

or accessories and repair and servicing of equipment shall be

performed only by a qualified agency. The term "qualified agency"

means any individual, firm, corporation or company which either in

person or through a representative is engaged in and is responsible

for (a) the installation or replacement of gas piping or (b) the

connection, installation, repair or servicing of equipment, who is

experienced in such work, familiar with all precautions required

and has complied with all the requirements of the authority having

jurisdiction.

State of Massachusetts: The installation must be made by

a licensed plumber or gas fitter in the Commonwealth of

Massachusetts.

The installation must conform with local codes, or in the absence

of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA

54 or Natural Gas and Propane Installation Code, CSA B149.1.

*Available from the American National Standards Institute, Inc.,

11 West 42nd St., New York, NY 10036.
A manufactured home (USA only) or mobile home OEM installation

must conform with the Manufactured Home Construction and Safety

Standard, Title 24 CFR, Part 3280, or, when such a standard is not

applicable, the Standard for Manufactured Home Installations, ANSI

Z225.1, or Standard for Gas Equipped Recreational Vehicles and

Mobile Housing, CSA Z240.4.
High Altitudes

For altitudes/elevations above 2,000 feet (610m), input ratings should

be reduced at the rate of 4 percent for each 1,000 feet (305m) above

sea level, this may be accomplished by reducing manifold pressure.

The maximum allowable reduction in manifold pressure for Natural

gas shall be from 3.5" w.c. (.872kPa) to 2.8" w.c. (.697kPa). The

maximum allowable reduction in manifold pressure for Propane

(LP) gas shall be from 10.0" w.c. (2.49kPa) to 8.0" w.c. (1.99kPa).

For Canadian high altitude applications, this appliance is suitable

for installation at elevations between 0 feet (0m) and 4,500 feet

(1,372m) without change.

Model

DV-55E

Input BTU/HR (KW/H)

55,000 (16.1)

Height

26" (660mm)

Width

37" (940mm)

Depths with Shroud

15 3/4" (400mm)

Gas Inlet (Pipe)

1/2" (13mm)

Electrical - Unit has a 5' (1.5m) 3 pronged cordset for connec-

tion to an approved 115 VAC 60HZ maximum

AMPs - 5A wall receptacle.

Accessories for DV-55E Furnaces
Extended Vent Terminal

For walls up to 32" (813mm)

DVT-2

Floor Pad

DVP-1

INTRODUCTION

SPECIFICATIONS