Proper Main Burner Flame

The proper main burner flame will be a blue primary (inner) flame

with a larger, lighter blue secondary (outer) blue flame.

Figure 10

Cleaning Main Burner(s)

Remove main burner(s) and apply air pressure inside the throat and

ports of the main burner(s).
Removing Main Burner(s)

1. Remove front grill assembly.

2. Remove burner compartment access panel (2 screws).

3. Remove main burner(s) from burner compartment (2 screws

per main burner).

Removing Gas Valve

1. Remove front grill assembly.

2. Disconnect manifold union assembly at gas valve.

3. Remove (2) two 24 volt wires from gas valve. Label wires prior

to disconnection from gas valve.

4. Remove gas valve from gas valve bracket.
Removing Main Burner orifice(s)

1. Remove front grill assembly.

2. Remove burner compartment access panel (2 screws).

3. Disconnect manifold union assembly.

4. Disconnect manifold union assembly brackets (5 screws).
Removing Ignitor and Flame Sensor

1. Remove front grill assembly.

2. Remove ignitor from burner compartment (2 screws).

3. Remove flame sensor from burner compartment (1 screw).
Cleaning Combustion (Exchanger) Assembly

A QUALIFIED SERVICE PERSON should remove the

combustion (exchanger) assembly. Apply air pressure to the

inside of the combustion (exchanger) assembly in order to clear

all passageways.
Oiling

The blower motor has an oil hole located on each end of the motor.

Use #20 motor oil only. It is best to oil the motor several times

during the heating season using 2 or 3 drops each time.