Installing Wall Bracket (Figures 5 and 6)

After finding a location for the furnace, gas supply and vent, the

wall bracket must be positioned and installed. The bracket should

be mounted to the wall studs, if possible, or anchored solidly to

the wall. Use the (2) 10 x 1 1/2" (38mm) hex-head screws or (2)

plastic anchors provided. Drill (2) 5/16" (8mm) diameter holes

in wall if plastic anchors are used. Attach the two wall mounting

brackets to the casing back by using (4) 10 x 1/2" (13mm) hex-

head screws provided.

Figure 5

Figure 6

Figure 7

Figure 8

2" (51mm) TO 13" (330mm)

2" (51mm) TO 32" (813mm)

WALL

CASING

BACK

#10 X 1"

WALL MOUNTING BRACKET

WALL

BRACKET

#10 X 1/2"

#10 X 1/2"

4" (102mm)

WALL

INTAKE FLEX HOSE

WITH CLAMPS

EXHAUST

INTAKE AIR

MOUNTING PLATE

EXHAUST ELBOW MAY

BE CUT TO LENGTH

TO FIT VENT BOX.

SECURE IN PLACE

USING HOSE CLAMPS

PROVIDED.

KEEP CAP ON

UN-USED AIR

INTAKE OPENING

EXHAUST AIR

ORANGE SILICONE

ELBOW CONNECTOR

INTAKE AIR

BLACK FLEXIBLE HOSE