REqUIREMENTS FOR MASSACHUSETTS

For all side wall horizontally vented gas fueled equipment

installed in every dwelling, building or structure used in

whole or in part for residential purposes, including those

owned or operated by the Commonwealth and where the

side wall exhaust vent termination is less than seven (7) feet

above finished grade in the area of the venting, including but

not limited to decks and porches, the following requirements

shall be satisfied:

1. INSTALLATION OF CARBON MONOXIDE DETEC-

TORS. At the time of installation of the side wall horizontal

vented gas fueled equipment, the installing plumber or

gasfitter shall observe that a hard wired carbon monoxide

detector with an alarm and battery back-up is installed on

the floor level where the gas equipment is to be installed.

In addition, the installing plumber or gasfitter shall observe

that a battery operated or hard wired carbon monoxide

detector with an alarm is installed on each additional

level of the dwelling, building or structure served by

the side wall horizontal vented gas fueled equipment. It

shall be the responsibility of the property owner to secure

the services of qualified licensed professionals for the

installation of hard wired carbon monoxide detectors

a. In the event that the side wall horizontally vented gas

fueled equipment is installed in a crawl space or an

attic, the hard wired carbon monoxide detector with

alarm and battery back-up may be installed on the

next adjacent floor level.

b. In the event that the requirements of this subdivision

can not be met at the time of completion of installa-

tion, the owner shall have a period of thirty (30) days

to comply with the above requirements; provided,

however, that during said thirty (30) day period, a

battery operated carbon monoxide detector with an

alarm shall be installed.

2. APPROVED CARBON MONOXIDE DETECTORS.

Each carbon monoxide detector as required in accordance

with the above provisions shall comply with NFPA 720

and be ANSI/UL 2034 listed and IAS certified.

3. SIGNAGE. A metal or plastic identification plate shall be

permanently mounted to the exterior of the building at a

minimum height of eight (8) feet above grade directly in

line with the exhaust vent terminal for the horizontally

vented gas fueled heating appliance or equipment. The

sign shall read, in print size no less than one-half (1/2)

inch in size, “GAS VEnt DIRECtLY BELoW. KEEP

CLEAR OF ALL OBSTRUCTIONS”.

4. INSPECTION. The state or local gas inspector of the

side wall horizontally vented gas fueled equipment shall

not approve the installation unless, upon inspection, the

inspector observes carbon monoxide detectors and signage

installed in accordance with the provisions of 248 CMR

5.08(2)(a) 1 through 4.

(b) EXEMPTIONS: The following equipment is exempt

from 248 CMR 5.08(2)(a)1 through 4:

1. The equipment listed in Chapter 10 entitled

“Equipment Not Required To Be Vented” in the

most current edition of NFPA 54 as adopted by

the Board; and

2. Product Approved side wall horizontally vented

gas fueled equipment installed in a room or

structure separate from the dwelling, building or

structure used in whole or in part for residential

purposes.

(c) MANUFACTURER REQUIREMENTS - GAS

EQUIPMENT VENTING SYSTEM PROVIDED.

When the manufacturer of Product Approved side

wall horizontally vented gas equipment provides a

venting system design or venting system components

with the equipment, the instructions provided by the

manufacturer for installation of the equipment and

the venting system shall include:

1. Detailed instructions for the installation of the

venting system design or the venting system

components; and

2. A complete parts list for the venting system design

or venting system.

(e) A copy of all installation instructions for all Product

Approved side wall horizontally vented gas fueled

equipment, all venting instructions, all parts lists for

venting instructions, and/or all venting design instruc-

tions shall remain with the appliance or equipment

at the completion of the installation.