SERVICE

5-6

Manual 0-2807

5.05 Power Supply Parts

Replacement

WARNING

Disconnect primary power to the system before dis-
assembling the torch, leads, or power supply.

A. Left Side Panel Removal

1. Remove the five screws which secure the left side

panel (viewed from front of unit) to the frame as-
sembly.

A-02752

Ground

Wire

Screws

(5 places)

Left Side

Panel

Figure 5-3 Left Side Panel Removal

NOTE

There is a ground wire connection to the Left Side
Panel on the inside of the unit. There is no need to
disconnect the ground wire.

2. Carefully pull the Left Side Panel up and away

from the unit to gain access to the inside of the
unit.

3. To reinstall the left side panel do the following:

a. Place the left side panel onto the frame and

slide the top edge under the lip on the top of
the right side panel.

b. Reinstall all the screws to secure the left side

panel.

B. Fuse Replacement

1. Remove the left side panel per paragraph "A"

above.

2. Locate the internal fuse above the input power

contactor on the left side of the unit.

3. Replace the fuse (0.8 amp, 600V).

4. Reinstall the left side panel per paragraph "A"

above.

A-02745

Internal Fuse

0.8 Amps, 600V

Figure 5-4 Internal Fuse Location