Section 2: introduction, 01 scope of manual, 02 general description of system – Tweco 75XL Plus PAK Master Manuel d'utilisation

Page 15: 03 specifications/design features, Section 2, Introduction -1

Advertising
background image

Manual 0-2807

2-1

INTRODUCTION

SECTION 2:

INTRODUCTION

2.01 Scope of Manual

This manual contains descriptions, operating instructions
and basic maintenance procedures for the PAK Master

®

75XL Plus Automated Plasma Cutting Power Supply. Ser-
vice of this equipment is restricted to properly trained
personnel; unqualified personnel are strictly cautioned
against attempting repairs or adjustments not covered in
this manual, at the risk of voiding the Warranty.

Read this manual thoroughly. A complete understand-
ing of the characteristics and capabilities of this equip-
ment will assure the dependable operation for which it
was designed.

2.02 General Description of System

The Automated System includes a Power Supply, Torch
& Leads and Work Cable & Ring Terminal.

The Power Supply provides 60 amp maximum output
and includes all control circuitry, electrical and gas in-
puts and outputs, pilot circuitry, torch leads receptacle
and a work cable with ring terminal.

NOTE

The power supply can be ordered in various con-
figurations with various options factory installed.

A-02750

Torch and

Leads

Work Cable and

Ring Terminal

Power Supply

Figure 2-1 Pak Master 75XL Plus Automated

System

Various torches are available with the Power Supply. The
Machine Torch is available in a 180° configuration. Torch
leads are available in 25 ft (7.6 m), or 50 ft (15.2 m) lengths
with fittings for simple installation. Spare Parts Kits are
available for the torches which provide an assortment of
replacement torch parts.

NOTE

Refer to Section 2.04 for list of power supply op-
tions and accessories.

2.03 Specifications/Design Features

A. Power Supply Technical Specifications

The following specifications apply to the Power Supply
only:

1. Front Panel Controls

ON/OFF Switch, RUN/SET/LATCH Switch and
Output Current Control

2. Front Panel Indicators

AC

, TEMP , GAS

, DC

3. Rear Panel

Input Power Cable Strain Relief, Gas Connection, Gas
Regulator/Filter Assembly, Two Stage Air Filter, CNC
Connector

4. Input Power

Can be configured for the following:

208/230/240 VAC (±10%), 50/60 Hz, Single or Three-
Phase

380/415 VAC (±10%), 50/60 Hz, Three-Phase

460 VAC (±10%), 50/60 Hz, Single or Three-Phase

5. Output Power

Continuously variable from 15 to 60 Amps maximum

Advertising