3-5

INSTALLATION

B. Checking Air Quality

To test the quality of air, place the RUN/SET/LATCH
switch to SET position, place a welding filter lens in front
of the torch and turn on the gas. Any oil or moisture in
the air will be visible on the lens. Do not initiate an arc!

CAUTION

The air supply must be free of oil, moisture, and
other contaminants. Excessive oil and moisture
may cause double-arcing, rapid tip wear, or even
complete torch failure. Contaminants may cause
poor cutting performance and rapid electrode wear.

C. Gas Connections

The gas supply is connected to the Two Stage Air Line
Filter Assembly installed on the rear of the unit. The con-
nection is the same for compressed air or high pressure
gas cylinders.

Connect the gas supply as follows:

1. Connect the gas line to the Regulator / Filter As-

sembly inlet port as shown. The illustration shows
typical fittings as an example. Other fittings may
be used. Install the fittings and tighten.

NOTE

Supply hose must be at least #4 hose (1/4 in or 6
mm I.D.).

Two Stage Filter

Assembly

1/4 NPT to

#4 (6mm) Hose

Fitting

#4 (6mm) Gas

Supply Hose

Hose Clamp

A-02744

Figure 3-7 Gas Connection To Two Stage Filter

Assembly

D. Optional Air Line Filter Installation

Filtering is required when using air from a compressor to
insure that moisture and debris from the supply hose does
not enter the torch. Although the unit is standard with
the Two Stage Air Filter there is an Optional Single-Stage
Filter Assembly that may be used. Install the Optional
Single-Stage Filter as follows:

1. Connect the gas line to the Regulator / Filter As-

sembly inlet port as shown. The illustration shows
typical fittings as an example. Other fittings may
be used. Install the fittings and tighten.

NOTE

Supply hose must be at least #4 hose (1/4 in or 6
mm I.D.).

A-02753

1/4 NPT to
#4 (6mm)
Hose Fitting

Dry Air Filter
Assembly

#4 (6mm)
Gas Supply
Hose

Hose Clamp

Figure 3-8 Gas Connection to Optional Single-Stage

Filter Assembly

E. Using High Pressure Gas Cylinders

Refer to the following when using high pressure gas cyl-
inders as the gas supply:

Advertising