Tweco 75XL Plus PAK Master Manuel d'utilisation

Page 29

Advertising
background image

Manual 0-2807

3-11

INSTALLATION

CNC Knockout

A-02756

Rear Panel

1/2" (12.7 mm)

Strain Relief

(Customer Supplied)

Figure 3-13 Rear Panel Knockout Location

c. Locate the internal terminal block (TB) on the

Filter/Voltage Divider PC Board, located be-
hind the Logic PC Board. The terminal block
(TB) is plugged into a socket on the Filter/Volt-
age Divider PC Board.

Logic PC Board

A-02757

Internal Terminal

Block (TB)

Filter/Voltage Divider

PC Board

Figure 3-14 Internal Terminal Block Location

d. Feed the CNC cable through the strain relief

at the rear of the Power Supply, routing the
cable above the Logic PC Board to the Termi-
nal Block (TB).

Internal Terminal

Block (TB)

A-02758

CNC Cable Routing

Figure 3-15 Routing CNC Cable

e. Remove the terminal block from the socket and

connect the CNC cable to the terminal block
(TB) per the following chart (see NOTES after
chart):

TB

Connection

Description

1

Power Supply Output Voltage (ARC V +)

2

Power Supply Output Voltage (ARC V -)

3

High Side of START Signal (+15 vdc)

4

Low Side of START Signal (Common)

5

One Side of OK-To-Move Signal

6

Other Side of OK-To-Move Signal

Advertising